Channel 5 No function (when CH4 is set between 0-79 )
Channel 5 Speed (when CH4 is set between 80-239 )
0-255
Speed from slow to fast
Channel 5 Audio Sensitivity (when CH4 is set between 240-255 )
0-255
Audio sensitivity from less sensitive to highly sensitive
Channel 6 No function (when CH4 is set between 0-9 )
Channel 6 Strobe (when CH4 is set between 10-255 )
0-255
Strobe effect, from slow to fast (0-20 flashes/sec.)
Channel 7 Dimmer intensity
Maintenance
The Showtec Compact Power Lightset requires almost no maintenance. However, you should keep the
unit clean. Otherwise, the fixtures light-output will be significantly reduced. Disconnect the mains power
supply, and then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass
cleaner and a soft cloth. Do not use alcohol or solvents. Keep connections clean. Disconnect electric
power, and then wipe the connections with a damp cloth. Make sure connections are thoroughly dry
before linking equipment or supplying electric power.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
1. All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
2. There may not be any deformations on housings, fixations and installation spots.
3. Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
4. The electric power supply cables must not show any damages or material fatigue.
Replacing a Fuse
Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the
fuse burns out, the product will not function whatsoever. If this happens, follow the directions below to do
so.
1. Unplug the unit from electric power source.
2. Insert a flat-head screwdriver into a slot in the fuse cover. Gently pry up the fuse cover. The fuse will
come out.
3. Remove the used fuse. If brown or unclear, it is burned out.
4. Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to
use a fuse of the same type and specification. See the product specification label for details.
0-255
Gradual adjustment dimmer intensity from 0-100%