FAN COOLING
The unit's fan is controlled by built-in temperature sensor. When the temperature(NOW TEMPERATURE)
detected by the sensor is less than 40 Celsius, the fan will switch on discontinuously.
When the temperature exceeds 40 Celsius, the fan will switch on continuously.
OVER TEMPERATURE SOLVING
A. When the recorded maximum temperature exceeds 70 Celsius and the ambient temperature is below
70 Celsius, the LCD shows "OVER TEMPERATURE" and only 50% of output remains.
You may make RESET adjustment using menu 82 to resume normal output.
B. When the recorded maximum temperature exceeds 70 Celsius and the ambient temperature is also over
70 Celsius, the LCD shows "OVER TEMPERATURE" and only 50% of output remains.
You can not make any adjustments until over temperature is solved.
C. In normal use, whenever over temperature occurs, the LCD should show " OVER TEMPERATURE"
immediately and only 50% of output remains.
MASTER / SLAVE LINK UP
A. You can set up communications between several units using Master/Slave link up, the first unit serves as
the Master, and the others are Slaves. (See menu 6 UNIT SETUP.)
B. The Master unit transfers the DMX signal and Map input signal to the Slave unit using DMX cables,
the Slave transfers the DMX input signal only but not the Map input signal.
LOCK THE BUTTONS
After power on, the LCD shows general status and test messages. Press and hold down YES and NO buttons
simultaneously for three seconds, the LCD should show "L" in the down right corner indicating all the buttons
are locked. Press the two buttons for three seconds again, the "L" character disappears and the
buttons are unlocked.
In menu 311, you may also lock or unlock the buttons as described above.
In menu 311 or 41, if you don't make any adjustments within 10 minutes, the buttons should be locked
automatically, you may press and hold down YES and NO buttons for three seconds to unlock the buttons
and go on your setting. In other menus, if you don't make any adjustments within 10 minutes, the buttons
should be locked automatically, the LCD shows the status messages and you should restart your menu